摘要: 目的:评估植入性心脏复律除颤器与否对射血分数(LVEF)在30%—35%的心衰患者的影响。 设计、参与及参与者:一项回顾性队列研究。国家心血管数据注册ICD登记数据中医保人员(NCDR,2006年1月1日至2007年12月31日) ...
原文:

Importance Clinical trials of prophylactic implantable cardioverter-defibrillators (ICDs) have included a minority of patients with a left ventricular ejection fraction (LVEF) between 30% and 35%. Because a large number of ICDs in the United States are implanted in such patients, it is important to study survival associated with this therapy.
Objective To characterize patients with LVEF between 30% and 35% and compare the survival of those with and without ICDs.
Design, Setting, and Participants Retrospective cohort study of Medicare beneficiaries in the National Cardiovascular Data Registry ICD registry (January 1, 2006, through December 31, 2007) with an LVEF between 30% and 35% who received an ICD during a heart failure hospitalization and similar patients in the Get With The Guidelines–Heart Failure (GWTG-HF) database (January 1, 2005, through December 31, 2009) with no ICD. The analysis was repeated in patients with an LVEF less than 30%. There were 3120 patients with an LVEF between 30% and 35% (816 in matched cohorts) and 4578 with an LVEF less than 30% (2176 in matched cohorts). Propensity score matching and Cox models were applied.
Main Outcomes and Measures The primary outcome was all-cause mortality; data were obtained from Medicare claims through December 31, 2011.
Results There were no significant differences in the baseline characteristics of the matched groups (n = 408 for both groups). Among patients with an LVEF between 30% and 35%, there were 248 deaths in the ICD Registry group, within a median follow-up of 4.4 years (interquartile range, 2.7-4.9) and 249 deaths in the GWTG HF group, within a median follow-up of 2.9 years (interquartile range, 2.1-4.4). The risk of all-cause mortality in patients with an LVEF between 30% and 35% and an ICD was significantly lower than that in matched patients without an ICD (3-year mortality rates: 51.4% vs 55.0%; hazard ratio, 0.83 [95% CI, 0.69-0.99]; P = .04). Presence of an ICD also was associated with better survival in patients with an LVEF less than 30% (3-year mortality rates: 45.0% vs 57.6%; 634 and 660 total deaths; hazard ratio, 0.72 [95% CI, 0.65-0.81]; P < .001) (P = .20 for interaction).
Conclusions and Relevance Among Medicare beneficiaries hospitalized for heart failure and with an LVEF between 30% and 35% and less than 30%, survival at 3 years was better in patients who received a prophylactic ICD than in comparable patients with no ICD. These findings support guideline recommendations to implant prophylactic ICDs in eligible patients with an LVEF of 35% or less. 